Bearing mounting

Shaft/housing fit screening (ISO 286 / OEM tables), clearance, and mounting practice.

mm

Recommended fits (screen)

Shaft
m6
Housing
H7
Clearance reduction
22.0 µm
Est. operating clearance
-13.0 µm
  • Rotating inner ring, moderate/heavy load — transition fit on shaft.
  • Ring temps (screening): inner 50 °C / outer 30 °C → thermal Δδ 6.0 µm.
  • Operating clearance is tight — consider C3/C4 or looser housing fit.

Press fit / oil injection

Use arbor press or hydraulic nut for interference seats. Never hammer on the outer ring of a ball bearing.

Thermal mounting

Heat inner ring (induction / oil bath, typically below 120 °C) for shrink fit; cool outer for housing interference when required.

Locknuts & sleeves

Adapter / withdrawal sleeves and locknuts for spherical and some tapered mounts — torque and tab washer per OEM.

Clearance check

Measure residual radial clearance after mounting when C3/C4 is specified for thermal or heavy fits.