Bearing lubrication

Viscosity ratio κ = ν/ν₁ and contamination eC drive ISO 281 aISO. Grease life is a screening estimate — confirm with OEM charts for critical duty.

mm
rpm
cSt
°C

Rated ν₁

0.8 cSt

κ

53.33

eC

0.5

Grease L10h (screen)

5,315 h

  • Oil bath / circulating oil: use operating viscosity at bearing temperature.
  • Grease: effective base-oil viscosity drops with temperature — derate accordingly.
  • Oil mist / jet: specialty high-speed practice — treat catalog n_lim carefully.

Feed κ and eC into the life calculator.